Filter Results By:

Products

Applications

Manufacturers

System Test

Testing conducted on a complete, integrated system to evaluate the system's compliance with its specified requirements .

See Also: Systems, Equipment, Test Systems, System Integrators


Showing results: 4201 - 4215 of 4427 items found.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device

    781630-07 - NI

    Ethernet GPIB Instrument Control Device - The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Brazil 127/220VAC

    781630-12 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - China 220VAC

    781630-10 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Swiss 220VAC

    781630-02 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Korea 220VAC

    781630-09 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000 , Ethernet GPIB Instrument Control Device - Universal Euro 240VAC

    781630-04 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000 , Ethernet GPIB Instrument Control Device - United States 120VAC

    781630-01 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - United Kingdom 240VAC

    781630-06 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • GPIB-ENET/1000, Ethernet GPIB Instrument Control Device - Taiwan 110VAC

    781630-11 - NI

    The GPIB‑ENET/1000 is an IEEE 488 controller device for computers with an Ethernet port. You can use this device to share a single GPIB system among many networked users or to control several test systems from a single networked host. The GPIB‑ENET/1000 features a password-protected web interface for easy configuration. It can also control IEEE 488 devices from anywhere on an Ethernet‑based (LAN) TCP/IP network (Gigabit, 100BASE‑TX, 10BASE‑T). Each device interfaces to and shares up to 14 GPIB devices from several network hosts, and you can control up to 100 GPIB‑ENET/1000 interfaces with a single computer. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.

  • ARINC825 Cards

    AIM GmbH

    AIM’s ARINC825 cards can work either with full functionality as an active CAN node for testing and simulating or in listening only mode for monitoring and recording purposes of Avionic CAN bus (ARINC825) applications on up to 4 electrically isolated CAN bus nodes concurrently. All nodes are in conformance with the ISO11898-1/-2 standard. They are accessible by software separately and can be used as 4 independent CAN bus nodes. An onboard IRIG-B time decoder allows users to accurately synchronize single or multiple modules to a common time source. All supported signals are available through front I/O and rear I/O interface. ARINC825 cards consist of FPGA based CAN interface controllers as well as a FPGA based 32-bit microcontroller core and a separate processor for IRIG-B synchronization with high resolution time stamping. All nodes are operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s with the intelligence to process scheduling of CAN frames in real time onboard to significantly off-load the host processor.For embedded applications the AMC825-4 PMC module is available in a conduction cooled version. Using AIM’s family of PCI, CPCI (3U and 6U) and VMEbus carrier cards for PMC our clients have off the shelf solutions in a broad range of card formats. ARINC825 (CAN bus) modules are delivered with an Application Programming Interface (API) and Driver Software compatible with Windows, Linux and VxWorks.An ARINC825 Resource Component is available for AIM’s PBA.pro™ databus test and analysis tool including Tx and Rx simulation capabilities, a Chronological Bus Monitor and support for decoding of payload data within CAN messages. This allows to implement a powerful ARINC825 (CAN bus) analyzer or a complete test system in conjunction with other AIM avionics databus interfaces and PBA.pro™ supported 3rd party hardware.

  • EMI Test Receiver

    SER - Saluki Technology Inc.

    Saluki SER series EMI receivers comply with CISPR 16-1-1 standard, integrated CISPR-AVG, CISPR-RMS, QPK detectors, and electromagnetic interference measurement. According to CISPR, EN, FCC and MIL standards, which is suitable for EMI testing in home appliances, lighting, automotive electronics, medical, and other industries. Combined with ETR PC measurement software and a wealth of test options, accurate automated testing is possible. The whole system is equipped with a spectrum analysis module and a tracking signal generator to meet the testing needs of users in different fields.

  • Resonance Dip Meter

    NRM-2 - National RF, Inc

    National RF’s Resonance Dip Meter is a test instrument used to determine the resonant frequency of a tuned circuit or resonant network, such as an antenna system. In addition, the unit may function as an RF detector, or a secondary frequency source. The instrument is analogous to the older vacuum tube “grid dip meter,” once popular in every electronic laboratory or radio station. Unique to this updated version is a buffered output that may drive a digital frequency counter for exact measurement of resonant frequency, or connected to an oscilloscope to be used as an RF detector and waveform/modulation monitor.

  • PXI Automotive Ethernet Interface Module

    NI

    The PXI Automotive Ethernet Interface Module communicates with Automotive Ethernet so that you can use the NI‑XNET driver or standard networking drivers to develop applications that require Automotive Ethernet to test and validate automotive electronic control units (ECUs). It provides up to four independent endpoints or up to two network terminal access points (TAPs). With onboard hardware timestamping and the ability to act as 802.1AS masters or slaves, the PXI Automotive Ethernet Interface Module can synchronize with an external network as well as the rest of a PXI system.

  • PXI Power Supply Modules

    Pickering Interfaces Ltd.

    Fixed power supply modules provide you with up to four separate voltage outputs isolated from the PXI backplane. Any combination of 3.3V, 5V, 12V or 15V can be specified with a maximum current capability of 4A for the 3.3V option; the software provides on/off control and status monitoring for each output. Dual programmable power supplies are capable of supplying up to 60 Watts of power. These are ideal solution for applications where a self contained test system with a high power supply power capability is required in a PXI format.

  • Becker Transponder Test Fixture

    TA-3400 - Tech-Aid Products

    This transponder test fixture is specific to the requirements for testing Becker Avionics Transponders and provides interface connectors for both the panel mount and remote systems. The panel also provides switches to implement Gillham code altitude as well as separate interfaces for an external parallel or serial encoder. The panel will interface with the RMU 5000 or standard control head. This fixture also comes with voltage and current meters along with an internal dimming source. This panel comes in the standard 19 inch rack width and measures 12 inches in depth.

Get Help